APC by Schneider Electric InRow OA End Aisle Containment Kit - 42UEnhance your data centers cooling efficiency and airflow control with the APC by Schneider Electric InRow OA End Aisle Containment Kit 42U. This translucent end of aisle containment solution is purpose built to pair with APCs InRow OA cooling architecture, delivering precise, scalable containment for high density racks. By physically separating the hot and cold airflow paths, this kit reduces recirculation, minimizes energy consumption, and creates a
Enhance your data center’s cooling efficiency and airflow control with the APC by Schneider Electric InRow OA End Aisle Containment Kit - 42U. This translucent end-of-aisle containment solution is purpose-built to pair with APC’s InRow OA cooling architecture, delivering precise, scalable containment for high-density racks. By physically separating the hot and cold airflow paths, this kit reduces recirculation, minimizes energy consumption, and creates a more predictable thermal environment. It’s ideal for mid-sized to large data centers looking to optimize cooling performance without sacrificing accessibility or visibility. With its durable construction and translucent panels, technicians can monitor cable routing and equipment status without repeatedly opening containment, keeping downtime to a minimum while maximizing uptime. Whether you’re retrofitting an existing row or building out a fresh deployment, this 42U containment kit provides a compact, modular solution that fits neatly at the end of your row for streamlined airflow management.
- Optimized airflow containment for InRow OA environments: The End Aisle Containment Kit channels cold supply air exactly where it’s needed, reducing hot air bypass and improving overall cooling efficiency. This targeted containment leads to lower facility energy use and can extend the life of your cooling infrastructure by maintaining consistent inlet temperatures for servers and storage devices.
- 42U height to cover standard racks with scalable coverage: Designed to integrate seamlessly with typical 42U racks, this kit provides substantial containment area while preserving access to critical components for maintenance and upgrades. The 42U profile supports dense rack configurations common in modern data centers, offering a practical balance between protection and serviceability.
- Translucent panels for visibility and safer operation: The translucent construction allows technicians to observe cabling, indicators, and equipment status without removing panels. This visibility supports proactive monitoring, faster fault diagnosis, and gentler, less disruptive maintenance windows.
- Durable, modular design for fast installation and serviceability: Built to withstand the rigors of data center environments, the kit features a modular layout that simplifies installation and future reconfiguration. Quick-connect fittings and standardized mounting points minimize downtime during deployment and upgrades, helping you achieve quicker time-to-value.
- Trusted APC by Schneider Electric brand for data center containment: APC is a recognized leader in data center cooling and containment solutions. This End Aisle Containment Kit is engineered to harmonize with APC’s InRow OA systems, delivering reliable performance, consistent airflow, and long-term operational savings for your IT infrastructure.
Technical Details of APC by Schneider Electric InRow OA End Aisle Containment Kit - 42U
- Brand: APC by Schneider Electric
- Product type: End Aisle Containment Kit
- Model/Series: InRow OA
- Size: 42U
- Finish/Appearance: Translucent panels
How to install APC by Schneider Electric InRow OA End Aisle Containment Kit - 42U
- Step 1: Prepare the installation area by confirming that all electrical work is de-energized according to facility safety procedures and that access to the data center aisle is clear for installation.
- Step 2: Inspect the containment kit to verify all components are present and undamaged. Compare the packing list with the delivered items and set aside any non-essential components to avoid interference during the initial setup.
- Step 3: Position the end-of-aisle containment panels to align with the existing InRow OA rack configuration. Use the manufacturer’s mounting guidelines to ensure square, level alignment, and stable attachment points for a secure fit.
- Step 4: Attach brackets, tracks, or fasteners as specified, securing the panels to racks or floor stands. Ensure that seals along panel edges are continuous to minimize air leakage and maximize containment efficiency.
- Step 5: Route and organize supply air paths by arranging cables and equipment within the containment zone. Install any optional accessories such as doors, gaskets, or cable grommets according to the installation guide to maintain airtight seals and easy access for maintenance.
- Step 6: Perform a containment verification by running the cooling system and monitoring airflow and temperatures at multiple locations inside the kit. Confirm that the cold supply air is directed toward server intakes and that hot air is effectively isolated from the cold aisle. Make minor seal adjustments if hotspots are detected.
- Step 7: Document the final configuration, including seal integrity and any adjustments made during commissioning. Schedule a follow-up check to ensure sustained performance as racks are loaded with equipment over time.
Frequently asked questions
- Q: What benefits does the InRow OA End Aisle Containment Kit offer for my data center? A: It provides targeted containment at the end of rows, reduces hot air recirculation, and enhances cooling efficiency, which can lower energy costs and improve system reliability for high-density deployments.
- Q: Is this kit compatible with existing APC InRow OA systems? A: Yes, the kit is designed to integrate with APC InRow OA configurations, offering a cohesive solution that aligns airflow with the cooling strategy of InRow OA deployments.
- Q: What maintenance is required after installation? A: Regular inspections of seals, gaskets, and panels are advisable, along with periodic airflow and temperature checks to ensure ongoing containment performance and energy savings.
- Q: Can the containment kit be expanded or reconfigured later? A: The modular design supports reconfigurations and adaptations as your data center evolves, making it easier to adjust containment coverage in response to changing rack layouts or density.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.